    <ArticleTitle>Investigation of Leakage Current and Surface Temperature of 230 kV Composite Insulator Under the Influence of Moisture and Contamination Conditions (Retracted)</ArticleTitle>
    <VernacularTitle>بررسی جریان نشتی و دمای سطح مقره‌ کامپوزیتی 230 کیلوولت در شرایط رطوبت و ریزگرد (بازپس گرفته شده)</VernacularTitle>
    <FirstPage>180</FirstPage>
    <LastPage>188</LastPage>
    <ELocationID EIdType="doi" />
    <Language>fa</Language>
    <AuthorList>
      <Author>
        <FirstName>سامان</FirstName>
        <LastName>محمدنبی</LastName>
        <Affiliation>دانشکده مهندسی مکانیک و انرژی</Affiliation>
      </Author>
      <Author>
        <FirstName>خسرو</FirstName>
        <LastName>رحمانی</LastName>
        <Affiliation>دانشکده مهندسی مکانیک و انرژی</Affiliation>
      </Author>
    </AuthorList>
    <History PubStatus="received">
      <Year>2020</Year>
      <Month>9</Month>
      <Day>12</Day>
    </History>
    <Abstract>&lt;p style="direction: ltr;"&gt;&lt;strong&gt;Retracted:&lt;/strong&gt;&lt;/p&gt;
&lt;pre id="tw-target-text" class="tw-data-text tw-text-large tw-ta" dir="ltr" tabindex="-1" data-placeholder="Translation" data-ved="2ahUKEwjVsdLj75qYAxUZzwIHHUesFXIQ3ewLegQIEhAV"&gt;&lt;strong&gt;&lt;span class="Y2IQFc" lang="en" style="font-family: verdana, geneva, sans-serif;"&gt;This article has been retracted by the editorial board due to extensive overlap with a related article previously published by the same authors in another journal, and the failure to properly disclose this overlap during the submission and review process. This decision is taken to safeguard the integrity of the scientific record and does not, in itself, constitute a definitive judgment regarding the authors' intent or bad faith.&lt;/span&gt;&lt;/strong&gt;&lt;/pre&gt;
&lt;p style="direction: ltr;"&gt;As moisture condenses on the surface of the contaminated insulators, the electrical conductivity of the insulator surface increases, resulting in a leakage current on the surface and causing the insulators to fail. Condensation of moisture on the insulator surface occurs due to the mechanism of radiation cooling, mainly in the early mornings of winters. In this case, the temperature of the insulator surface is lower than the dew point. In this paper, a sample of real fine dust collected from the dust center and chemical analysis and measurement of electrical conductivity in the wet state were performed. By simulating a 230-kV contaminated composite insulator in COMSOL Multiphysics software, the magnitude of leakage current was obtained and verified by an experimental test. Also, using heat transfer governing relations, the temperature of the insulator surface during the leakage current flow, was determined and compared with the images captured by the thermo-vision camera during the test. The results show that the leakage current and the surface temperature of the insulator increase with increasing the conduction and thickness of the contamination layer and consequently the probability of insulator failure also increases. Experimental testing shows that simulation of insulators with finite elements-based commercial software can be a reliable method for pre-analysis of insulators.&lt;/p&gt;</Abstract>
    <OtherAbstract Language="FA">&lt;p&gt;&lt;strong&gt;بازپس گرفته شده (Retracted)&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;این مقاله به دلیل هم&amp;zwnj;پوشانی گسترده با مقاله&amp;zwnj;ای مرتبط که پیش&amp;zwnj;تر توسط همین نویسندگان در نشریه دیگری منتشر شده است و عدم افشای مناسب این هم&amp;zwnj;پوشانی در فرایند ارسال و بازنگری، با تصمیم هیأت تحریریه بازپس&amp;zwnj;گرفته شده است. این تصمیم با هدف صیانت از صحت سابقه علمی اتخاذ شده و به&amp;zwnj;خودی&amp;zwnj;خود متضمن داوری قطعی درباره قصد یا سوءنیت نویسندگان نیست.&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;با چگالش رطوبت روی سطح مقره&amp;zwnj;های آلوده به ریزگرد، هدایت الکتریکی مقره بالا رفته و به تبع آن جریان نشتی روی سطح ایجاد شده و باعث از کارافتادگی مقره&amp;zwnj;ها می&amp;zwnj;شود. چگالش رطوبت روی سطح، در اثر مکانیزم سردشدن تشعشعی و عمدتاً اوایل صبح و در فصل زمستان اتفاق می&amp;zwnj;افتد. در این حالت دمای سطح مقره از نقطه شبنم کمتر است. در این مقاله ضمن بررسی مکانیزم سردشدن تشعشعی، یک نمونه ریزگرد واقعی جمع&amp;zwnj;آوری شده از کانون ریزگرد، آنالیز شیمیایی و هدايت الكتريكي آن&amp;zwnj; در حالت مرطوب اندازه&amp;zwnj;گیری شده است. با شبیه&amp;zwnj;سازی مقره کامپوزیتی kV 230 آلوده به ریزگرد در نرم&amp;zwnj;افزار کامسول، جریان نشتی به دست آمده و با آزمون تجربی صحت&amp;zwnj;سنجی شده است. همچنین با استفاده از روابط انتقال حرارت، دمای سطح مقره هنگام عبور جریان نشتی تعیین و با مقادیر ثبت&amp;zwnj;شده توسط دوربین ترموویژن در هنگام آزمون، مقایسه گردیده است. نتایج نشان می&amp;zwnj;دهد که جریان نشتی و دمای سطح مقره با افزایش هدایت و ضخامت لایه آلودگی افزایش یافته و به تبع آن احتمال از کار افتادگی مقره نیز بالا می&amp;zwnj;رود. آزمون تجربی نشان داد که شبیه&amp;zwnj;سازی مقره با نرم&amp;zwnj;افزارهای تجاری موجود، می&amp;zwnj;تواند روش قابل اعتمادی برای تحلیل پیش&amp;zwnj;دستانه جهت ارزیابی مقره&amp;zwnj;ها به شمار رود.&lt;/p&gt;</OtherAbstract>